|
|
|
|
LEADER |
00000nam a22000003u 4500 |
001 |
b5647611 |
003 |
CoU |
005 |
20091106011257.0 |
006 |
m d f |
007 |
cr un |
008 |
091215e19960201dcu st f0|||||eng|d |
035 |
|
|
|a (TOE)ost207037
|
035 |
|
|
|a (TOE)207037
|
040 |
|
|
|a TOE
|c TOE
|
049 |
|
|
|a GDWR
|
072 |
|
7 |
|a 43
|2 edbsc
|
086 |
0 |
|
|a E 1.99:ANL/ASD/RP--87244
|
086 |
0 |
|
|a E 1.99:ANL/ASD/RP--87244
|
088 |
|
|
|a ANL/ASD/RP--87244
|
088 |
|
|
|a DE96005957
|
245 |
0 |
0 |
|a VME system monitor board
|h [electronic resource]
|
260 |
|
|
|a Washington, D.C. :
|b United States. Dept. of Energy ;
|a Oak Ridge, Tenn. :
|b distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy,
|c 1996.
|
300 |
|
|
|a 59 p.
|
336 |
|
|
|a text
|b txt
|2 rdacontent.
|
337 |
|
|
|a computer
|b c
|2 rdamedia.
|
338 |
|
|
|a online resource
|b cr
|2 rdacarrier.
|
500 |
|
|
|a Published through the Information Bridge: DOE Scientific and Technical Information.
|
500 |
|
|
|a 02/01/1996.
|
500 |
|
|
|a "ANL/ASD/RP--87244"
|
500 |
|
|
|a "DE96005957"
|
520 |
3 |
|
|a Much of the machinery throughout the APS will be controlled by VME based computers. In order to increase the reliability of the system, it is necessary to be able to monitor the status of each VME crate. In order to do this, a VME System Monitor was created. In addition to being able to monitor and report the status (watchdog timer, temperature, CPU (Motorola MVME 167) state (status, run, fail), and the power supply), it includes provisions to remotely reset the CPU and VME crate, digital I/O, and parts of the transition module (serial port and ethernet connector) so that the Motorla MVME 712 is not needed. The standard VME interface was modified on the System Monitor so that in conjunction with the Motorola MVME 167 a message based VXI interrupt handler could is implemented. The System Monitor is a single VME card (6U). It utilizes both the front panel and the P2 connector for I/O. The front panel contains a temperature monitor, watchdog status LED, 4 general status LEDs, input for a TTL interrupt, 8 binary inputs (24 volt, 5 volt, and dry contact sense), 4 binary outputs (dry contact, TTL, and 100 mA), serial port (electrical RS-232 or fiber optic), ethernet transceiver (10 BASE-FO or AUI), and a status link to neighbor crates. The P2 connector is used to provide the serial port and ethernet to the processor. In order to abort and read the status of the CPU, a jumper cable must be connected between the CPU and the System Monitor.
|
536 |
|
|
|b W-31109-ENG-38.
|
650 |
|
7 |
|a Advanced Photon Source.
|2 local.
|
650 |
|
7 |
|a Monitors.
|2 local.
|
650 |
|
7 |
|a Design.
|2 local.
|
650 |
|
7 |
|a Computerized Control Systems.
|2 local.
|
650 |
|
7 |
|a Computer Architecture.
|2 local.
|
650 |
|
7 |
|a Electronic Circuits.
|2 local.
|
650 |
|
7 |
|a Particle Accelerators ;99 Mathematics, Computers, Information Science, Management, Law, Miscellaneous.
|2 edbsc.
|
710 |
2 |
|
|a Argonne National Laboratory.
|4 res.
|
710 |
2 |
|
|a United States.
|b Department of Energy.
|4 spn.
|
710 |
2 |
|
|a United States.
|b Department of Energy.
|b Office of Scientific and Technical Information.
|4 dst.
|
856 |
4 |
0 |
|u http://www.osti.gov/servlets/purl/207037-VDGPbY/webviewable/
|z Online Access
|
907 |
|
|
|a .b56476115
|b 03-06-23
|c 12-19-09
|
998 |
|
|
|a web
|b 12-19-09
|c f
|d m
|e p
|f eng
|g dcu
|h 0
|i 1
|
956 |
|
|
|a Information bridge
|
999 |
f |
f |
|i 7899c34a-e002-5b5f-9e92-2a9e835b8001
|s 1f0f31a4-97b1-5db7-aa2a-5e83c9903a41
|
952 |
f |
f |
|p Can circulate
|a University of Colorado Boulder
|b Online
|c Online
|d Online
|e E 1.99:ANL/ASD/RP--87244
|h Superintendent of Documents classification
|i web
|n 1
|