Application of atomic magnetometry in magnetic particledetection [electronic resource]

Atomic Magnetometer Magnetic Nanoparticles Biomarkers.

Saved in:
Bibliographic Details
Online Access: Online Access (via OSTI)
Format: Government Document Electronic eBook
Language:English
Published: Washington, D.C. : Oak Ridge, Tenn. : United States. Department of Energy. ; distributed by the Office of Scientific and Technical Information, U.S. Department of Energy, 2006.
Subjects:
Description
Summary:Atomic Magnetometer Magnetic Nanoparticles Biomarkers.
Abstract:We demonstrate the detection of magnetic particles carriedby water in a continuous flow using an atomic magnetic gradiometer.Studies on three types of magnetic particles are presented: a singlecobalt particle (diameter ̃;150 mum, multi-domain), a suspension ofsuperparamagnetic magnetite particles (diameter ̃;1 mum), andferromagnetic cobalt nanoparticles (diameter ̃;10 nm, 120 kA/mmagnetization). Estimated detection limits are 20 mum diameter for asingle cobalt particle at a water flow rate 30 ml/min, 5x103 magnetiteparticles at 160 ml/min, and 50 pl for the specific ferromagnetic fluidat 130 ml/min. Possible applications of our method arediscussed.
Item Description:Published through SciTech Connect.
09/17/2006.
"lbnl--61614"
": KC0203010"
Applied Physics Letters 89 22 ISSN 0003-6951; APPLAB FT.
Xu, Shoujun; Donaldson, Marcus H.; Pines, Alexander; Rochester,Simon M.; Budker, Dmitry; Yashchuk, Valeriy V.
Ernest Orlando Lawrence Berkeley NationalLaboratory, Berkeley, CA (US)