Choice and test of the photomultipliers for the Large Angle electromagnetic shower Calorimeter on the CLAS detector at CEBAF [electronic resource]

Saved in:
Bibliographic Details
Online Access: Online Access
Corporate Author: Thomas Jefferson National Accelerator Facility (U.S.) (Researcher)
Format: Government Document Electronic eBook
Language:English
Published: Washington, D.C. : Oak Ridge, Tenn. : United States. Dept. of Energy. Office of Energy Research ; distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy, 1998.
Subjects:

MARC

LEADER 00000nam a22000003u 4500
001 b7318578
003 CoU
005 20091216000000.0
006 m o d f
007 cr |||||||||||
008 130211e19980401dcu o| f0|||||eng|d
035 |a (TOE)ost899880 
035 |a (TOE)899880 
040 |a TOE  |c TOE 
049 |a GDWR 
072 7 |a 43  |2 edbsc 
072 7 |a 46  |2 edbsc 
086 0 |a E 1.99: doe/er/40150-4227 
086 0 |a E 1.99:jlab-phy-98-87 
086 0 |a E 1.99: doe/er/40150-4227 
088 |a jlab-phy-98-87 
088 |a doe/er/40150-4227 
245 0 0 |a Choice and test of the photomultipliers for the Large Angle electromagnetic shower Calorimeter on the CLAS detector at CEBAF  |h [electronic resource] 
260 |a Washington, D.C. :  |b United States. Dept. of Energy. Office of Energy Research ;  |a Oak Ridge, Tenn. :  |b distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy,  |c 1998. 
300 |a 403-410 :  |b digital, PDF file. 
336 |a text  |b txt  |2 rdacontent. 
337 |a computer  |b c  |2 rdamedia. 
338 |a online resource  |b cr  |2 rdacarrier. 
500 |a Published through the Information Bridge: DOE Scientific and Technical Information. 
500 |a 04/01/1998. 
500 |a "jlab-phy-98-87" 
500 |a " doe/er/40150-4227" 
500 |a Nuclear Instruments and Methods in Physics Research, Section A 406 ISSN 0168-9002; NIMAER FT. 
500 |a P. Rossi; V. Sapunenko; E. Shirokov; M. Taiuti; M. Anghinolfi; P. Corvisiero; V. Mokeev; A. Rottura; A. Deppman; E. Golovach; M. Battaglieri; A. Longhi; H. Avakian; V. Giourdjian; M. Castoldi; F. Ronchetti; M. Ripania. 
520 3 |a The choice of the photomultipliers for the Large Angle electromagnetic Calorimeter to be installed on the CLAS detector at CEBAF is reported. The results of comparative tests on three different types of tubes are presented; then the CAMAC-based apparatus that was used to measure the most relevant parameters of a large number of photomultipliers of the chosen type is described and results are discussed. 
536 |b AC05-84ER40150. 
650 7 |a Performance Testing.  |2 local. 
650 7 |a Cebaf Accelerator.  |2 local. 
650 7 |a Calorimeters.  |2 local. 
650 7 |a Photomultipliers.  |2 local. 
650 7 |a Particle Accelerators.  |2 edbsc. 
650 7 |a Instrumentation Related To Nuclear Science And Technology.  |2 edbsc. 
710 2 |a Thomas Jefferson National Accelerator Facility (U.S.).  |4 res. 
710 1 |a United States.  |b Department of Energy.  |b Office of Energy Research.  |4 spn. 
710 1 |a United States.  |b Department of Energy.  |b Office of Scientific and Technical Information.  |4 dst. 
856 4 0 |u http://www.osti.gov/servlets/purl/899880-PITnm4/  |z Online Access 
907 |a .b73185784  |b 03-07-23  |c 02-11-13 
998 |a web  |b 02-11-13  |c f  |d m   |e p  |f eng  |g dcu  |h 0  |i 2 
956 |a Information bridge 
999 f f |i a7f11ede-3e62-5f65-8fac-7c51cdb83f40  |s d3e3f9c0-6f3a-5f3f-83d0-d2fea44b0539 
952 f f |p Can circulate  |a University of Colorado Boulder  |b Online  |c Online  |d Online  |e E 1.99: doe/er/40150-4227  |h Superintendent of Documents classification  |i web  |n 1