Behavior of implanted D and He in pyrolytic graphite [electronic resource]

Saved in:
Bibliographic Details
Online Access: Online Access
Format: Government Document Electronic eBook
Language:English
Published: Washington, D.C. : Oak Ridge, Tenn. : United States. Department of Energy. ; distributed by the Office of Scientific and Technical Information, U.S. Department of Energy, 1978.
Subjects:

MARC

LEADER 00000nam a22000003u 4500
001 b7799761
003 CoU
005 20140709221639.5
006 m o d f
007 cr |||||||||||
008 140801e19780101||| o| f1|||||eng|d
035 |a (TOE)ost6857333 
035 |a (TOE)6857333 
040 |a TOE  |c TOE 
049 |a GDWR 
072 7 |a 36  |2 edbsc 
086 0 |a E 1.99:conf-780431-12 
086 0 |a E 1.99:conf-780431-12 
088 |a conf-780431-12 
245 0 9 |a Behavior of implanted D and He in pyrolytic graphite  |h [electronic resource] 
260 |a Washington, D.C. :  |b United States. Department of Energy. ;  |a Oak Ridge, Tenn. :  |b distributed by the Office of Scientific and Technical Information, U.S. Department of Energy,  |c 1978. 
300 |a Pages: 27 :  |b digital, PDF file. 
336 |a text  |b txt  |2 rdacontent. 
337 |a computer  |b c  |2 rdamedia. 
338 |a online resource  |b cr  |2 rdacarrier. 
500 |a Published through SciTech Connect. 
500 |a 01/01/1978. 
500 |a "conf-780431-12" 
500 |a 3. conference on plasma interaction in controlled fusion devices, Abingdon, Oxfordshire, UK, 3 Apr 1978. 
500 |a Roth, J.; Blewer, R. S.; Langley, R. A. 
500 |a Sandia Labs., Albuquerque, N.Mex. (USA) 
500 |a Max-Planck-Institut fuer Plasmaphysik, Garching/Muenchen (Germany, F.R.) 
520 3 |a The behavior of deuterium and helium implanted near room temperature at 8 keV into prism plane oriented graphite was studied as a function of implantation fluence and post-anneal temperature. Depth profiles of the implanted species were measured by proton backscattering. Quantitative thermal desorption measurements were performed to study the species emitted from the sample during ramp heating to 950/sup 0/C. A summary of the results follows: (1) 100% trapping was observed for D implants up to fluence of 10/sup 18/ D/cm/sup 2/. (2) The measured mean ranges and full widths for D implants agreed with previous measurements but exceed the calculated ..delta..Rp for fluences up to 10/sup 18/ D/cm/sup 2/; above this fluence the profiles broaden toward the surface with the rear edge remaining at a constant depth. 
536 |b W-7405-ENG-26. 
536 |b EY-76-C-04-0789. 
650 7 |a Deuterium Ions.  |2 local. 
650 7 |a Diffusion.  |2 local. 
650 7 |a Helium Ions.  |2 local. 
650 7 |a Pyrolytic Carbon.  |2 local. 
650 7 |a Ion Implantation.  |2 local. 
650 7 |a Kev Range 01-10.  |2 local. 
650 7 |a Trapping.  |2 local. 
650 7 |a Very High Temperature.  |2 local. 
650 7 |a Carbon.  |2 local. 
650 7 |a Charged Particles.  |2 local. 
650 7 |a Elements.  |2 local. 
650 7 |a Energy Range.  |2 local. 
650 7 |a Ions.  |2 local. 
650 7 |a Kev Range.  |2 local. 
650 7 |a Nonmetals.  |2 local. 
650 7 |a Materials Science.  |2 edbsc. 
710 1 |a United States.  |b Department of Energy.  |4 spn. 
710 1 |a United States.  |b Department of Energy.  |b Office of Scientific and Technical Information.  |4 dst. 
856 4 0 |u http://www.osti.gov/servlets/purl/6857333/  |z Online Access 
907 |a .b7799761x  |b 03-08-23  |c 08-01-14 
998 |a web  |b 08-01-14  |c f  |d m   |e p  |f eng  |g    |h 9  |i 1 
956 |a Information bridge 
999 f f |i 88661173-a43d-5788-af9d-95c335dd08f4  |s 7153876f-8bb9-5104-821a-2a7c4cf0180a 
952 f f |p Can circulate  |a University of Colorado Boulder  |b Online  |c Online  |d Online  |e E 1.99:conf-780431-12  |h Superintendent of Documents classification  |i web  |n 1