ALARA and decommissioning [electronic resource] : The Fort St. Vrain experience.

Saved in:
Bibliographic Details
Online Access: Online Access (via OSTI)
Corporate Author: U.S. Nuclear Regulatory Commission (Researcher)
Format: Government Document Electronic eBook
Language:English
Published: Rockville, Md. : Oak Ridge, Tenn. : U.S. Nuclear Regulatory Commission ; distributed by the Office of Scientific and Technical Information, U.S. Department of Energy, 1995.
Subjects:

MARC

LEADER 00000nam a22000003u 4500
001 b9121799
003 CoU
005 20180223220620.7
006 m o d f
007 cr |||||||||||
008 190514e19950301||| o| f1|||||eng|d
035 |a (TOE)ost54678 
035 |a (TOE)54678 
040 |a TOE  |c TOE 
049 |a GDWR 
072 7 |a 21  |2 edbsc 
072 7 |a 22  |2 edbsc 
072 7 |a 05  |2 edbsc 
086 0 |a E 1.99:conf-940505-- 
086 0 |a E 1.99:nureg/cp--0143 
086 0 |a E 1.99: bnl-nureg--52440 
086 0 |a E 1.99:conf-940505-- 
088 |a conf-940505-- 
088 |a bnl-nureg--52440 
088 |a nureg/cp--0143 
245 0 0 |a ALARA and decommissioning  |h [electronic resource] :  |b The Fort St. Vrain experience. 
260 |a Rockville, Md. :  |b U.S. Nuclear Regulatory Commission ;  |a Oak Ridge, Tenn. :  |b distributed by the Office of Scientific and Technical Information, U.S. Department of Energy,  |c 1995. 
300 |a pp. 679-689 :  |b digital, PDF file. 
336 |a text  |b txt  |2 rdacontent. 
337 |a computer  |b c  |2 rdamedia. 
338 |a online resource  |b cr  |2 rdacarrier. 
500 |a Published through SciTech Connect. 
500 |a 03/01/1995. 
500 |a "nureg/cp--0143" 
500 |a " bnl-nureg--52440" 
500 |a "conf-940505--" 
500 |a "TI95008770" 
500 |a 3. international workshop on implementation of ALARA at nuclear power plants, Long Island, NY (United States), 8-11 May 1994. 
500 |a Borst, T.; Niehoff, M. [Public Service Co. of Colorado, Platteville, CO (United States)]; Zachary, M. [Scientific Ecology Group, Platteville, CO (United States)] 
520 3 |a The Fort St. Vrain Nuclear Generating Station, the first and only commercial High Temperature Gas Cooled Reactor to operate in the United States, completed initial fuel loading in late 1973 and initial startup in early 1974. Due to a series of non-nuclear technical problems, Fort St. Vrain never operated consistently, attaining a lifetime capacity factor of slightly less than 15%. In August of 1989, the decision was made to permanently shut down the plant due to control rod drive and steam generator ring header failures. Public Service Company of Colorado elected to proceed with early dismantlement (DECON) as opposed to SAFSTOR on the bases of perceived societal benefits, rad waste, and exposure considerations, regulatory uncertainties associated with SAFSTOR, and cost. The decommissioning of Fort St. Vrain began in August of 1992, and is scheduled to be completed in early 1996. Decommissioning is being conducted by a team consisting of Westinghouse, MK-Ferguson, and Scientific Ecology Group. Public Service Company of Colorado as the licensee provides contract management and oversight of contractor functions. An aggressive program to maintain project radiation exposures As Low As Reasonably Achievable (ALARA) has been established, with the following program elements: temporary and permanent shielding contamination control; mockup training; engineering controls; worker awareness; integrated work package reviews communication; special instrumentation; video camera usage; robotics application; and project committees. To date, worker exposures have been less than project estimates. from the start of the project through Februrary of 1994, total exposure has been 98.666 person-rem, compared to the project estimate of 433 person-rem and goal of 347 person-rem. The presentation will discuss the site characterization efforts, the radiological performance indicator program, and the final site release survey plans. 
650 7 |a Vrain Reactor.  |2 local. 
650 7 |a Decommissioning.  |2 local. 
650 7 |a Personnel.  |2 local. 
650 7 |a Training.  |2 local. 
650 7 |a Alara.  |2 local. 
650 7 |a Occupational Exposure.  |2 local. 
650 7 |a Control.  |2 local. 
650 7 |a Contamination.  |2 local. 
650 7 |a Mockup.  |2 local. 
650 7 |a Shielding.  |2 local. 
650 7 |a Planning.  |2 local. 
650 7 |a Work.  |2 local. 
650 7 |a Nuclear Power Reactors And Associated Plants.  |2 edbsc. 
650 7 |a Nuclear Reactor Technology.  |2 edbsc. 
650 7 |a Nuclear Fuels.  |2 edbsc. 
710 2 |a U.S. Nuclear Regulatory Commission.  |4 res. 
710 1 |a United States.  |b Department of Energy.  |b Office of Scientific and Technical Information.  |4 dst. 
856 4 0 |u http://www.osti.gov/scitech/biblio/54678  |z Online Access (via OSTI) 
907 |a .b91217994  |b 03-09-23  |c 05-12-17 
998 |a web  |b 05-20-19  |c f  |d m   |e p  |f eng  |g    |h 0  |i 2 
956 |a Information bridge 
999 f f |i da186d7f-cdd0-5f8f-ac09-87c6cd130445  |s cffebda6-04d7-53c3-be64-9adc0ba5333e 